March Pump’s industrial AC-2CP-MD is an American seal-less centrifugal magnetic drive pump ideal for applications such as chemical recirculation and chemical transfer. It is capable of generating a maximum flow of 5 gallons per minute at 2 feet, and its maximum head is 13 Feet (5.5PSI).

Unit
System
60Hz
US
Metric
Max Flow 5 GPM 18.9 LPM
Max Head 13 FT 4 M
Power 0.025 HP 0.019 KW
50Hz
US
Metric
4.9 GPM 18.5 LPM
8.9 FT 2.7 M
0.025 HP 0.019 KW
Electrical/Air: 115V 50/60Hz
Inlet: 3/8″FPT & 3/4″MPT
Outlet: 1/4″MPT

Description

AC-2CP-MD Mag Drive Pump

The March Pump AC-2CP-MD Mag Drive Pump is an American-made, seal-less centrifugal magnetic drive pump designed for reliable chemical recirculation and chemical transfer applications. Its magnetic drive design eliminates the need for a traditional shaft seal, helping reduce the risk of leakage and minimizing maintenance requirements when handling demanding fluids.

The AC-2CP-MD is capable of delivering a maximum flow rate of 5 GPM at 2 feet and provides a maximum head of 13 feet (5.5 PSI). This compact chemical transfer pump is suitable for applications involving mildly or highly corrosive chemicals, acids, and solvents, depending on the chemical compatibility of the wetted materials.

The standard wet end is constructed from Polypropylene, Viton, Ceramic, and Ceramic Magnet, providing dependable performance in a wide range of chemical-handling applications. The pump features a 3/8″ female pipe thread inlet and a 1/4″ male pipe thread outlet, making it suitable for compact fluid transfer and circulation systems.

The standard motor configuration is available with a 1-phase 115V, 0.033 HP fan-cooled motor, operating at 50/60 Hz. The pump can also be configured with a 230V, 0.025 HP motor depending on the application and requirements. Performance may vary between 50 Hz and 60 Hz operation.

With a maximum internal pressure of 50 PSI and a maximum liquid temperature of 190°F (87°C), the March AC-2CP-MD is designed for dependable operation in various industrial and chemical-processing environments.

Key Features

  • Seal-less centrifugal magnetic drive pump
  • Suitable for chemical recirculation and chemical transfer
  • Ideal for mildly and highly corrosive chemicals, acids, and solvents
  • Maximum flow: 5 GPM at 2 ft
  • Maximum head: 13 ft (5.5 PSI)
  • Maximum internal pressure: 50 PSI
  • Maximum liquid temperature: 190°F (87°C)
  • Wetted materials: Polypropylene, Viton, Ceramic, and Ceramic Magnet
  • Inlet: 3/8″ FPT
  • Outlet: 1/4″ MPT
  • Electrical supply: 115V, 50/60Hz
  • Compact and low-maintenance magnetic drive design

Applications

The AC-2CP-MD Mag Drive Pump can be used in a variety of industrial fluid-handling applications, including chemical recirculation systems, chemical transfer, laboratory equipment, process systems, and other applications requiring reliable pumping of compatible corrosive liquids.

Before selecting the pump, it is important to verify chemical compatibility, operating temperature, pressure, flow requirements, and electrical specifications for your specific application. Contact us to confirm whether the March AC-2CP-MD Mag Drive Pump is suitable for your required chemical or fluid-handling system.

MARCH PUMPS MA LC-2CP-MD 230V

Brand

March Pumps - Dubai, UAE

Climax Marine Services specializes in supply of different Brands and types of Marine Sea Water Pump that are used in various applications. We carry a wide range of Sea water pumps such as March Pump,K2, Scot Pump,  Oberdorfer, Calpeda etc. We have also Fresh/Chill water pumps, Condensation Pump, Macerator Pump & Pump Mechanical Seal. Find your next Marine Sea Water Pump online with us and delivered to your door step in Dubai, Oman, Qatar, Bahrain, Saudia Arabia and Kuwait.

Port Size:
Inlet Port is 3/8 inch Female NPT and 3/4 inch Male NPT Inlet, Discharge Port is 1/4 inch Male NPT Outlet.

 

Motor Specs :
1/40 Horsepower, 3450 RPM, 115 Volts AC, Single Phase, Open Fan Cooled. 3 foot long cord.

There are many applications that the March AC2CPMD115V are used in. Typical applications for this pump include etching equipment, photographic processing equipment, ice makers, ice flakers, plate processors, and marine air conditioning. The AC2CPMD has pumped has pumped Acetic Acid, Acetone, Ammonium Sulfate, Citric Acid, Ethylene Glycol, Ferric Sulfate, Hydrogen Peroxide, Potassium Hydroxide, Sodium Chloride, Fresh Water, Salt Water, and many more chemicals. Liquids containing ferrous metal fines should not be pumped. This pump may have to be modified to pump liquids or chemicals with specific gravities, viscosities, or elevated temperatures different then ambient water. A magnetic drive pump is sealless, preventing any leakage that is normally associated with a conventional seal pump. Not only does the absence of a seal prevent the leakage of potentially dangerous and expensive liquids, it reduces maintenance time spent on the pump. In any magnetic drive pump, there are only two moving parts, the drive magnet and the impeller. With only two moving parts, there is little to break in the pump, and this pump is serviceable with a screwdriver. The simpler the pump, the less chance there is for failure. A magnetic drive pump is your answer to for a long lasting, dependable, reliable pump. Install the pump as near to the suction source and as low as possible with a flooded suction. The Pump should be mounted horizontally on a foundation secured by anchor bolts on a flat, stable surface or supports which are suitable to prevent movement of the pump and motor when in operation. It is advisable to mount the motor on a dampening/insulation surface to reduce noise and vibration caused by the moving components while operation. Always ensure that the outlet port is higher than the inlet port. This allows a path for the air to escape through. If the outlet is not higher than air can build up and may cause problems within the system. The pump should never be mounted vertically with the pump head at the lowest point. This will create an air pocket within the pump chamber and may cause problems.

Install the pump as near to the suction source and as low as possible with a flooded suction. The Pump should be mounted horizontally on a foundation secured by anchor bolts on a flat, stable surface or supports which are suitable to prevent movement of the pump and motor when in operation. It is advisable to mount the motor on a dampening/insulation surface to reduce noise and vibration caused by the moving components while operation. Always ensure that the outlet port is higher than the inlet port. This allows a path for the air to escape through. If the outlet is not higher than air can build up and may cause problems within the system. The pump should never be mounted vertically with the pump head at the lowest point. This will create an air pocket within the pump chamber and may cause problems.

March Pumps – AC-2CP-MD 115V, Open Air Magnetic Drive Pump – 0125-0069-0100

  • Polypropylene -Front and Rear Housing, Impeller
  • Viton -O-Ring
  • Ceramic -Shaft, Thrust Washer
  • Ceramic Magnet
Manufacturer Part Number AC-2CP-MD 115V
Max Flow 60Hz 5GPM
Max Head 60Hz 13 Feet
Max Flow 50Hz 18.5LPM
Max Head 50Hz 2.7M
Electrical & Voltage 115V 50/60Hz
Inlet 3/8″FPT & 3/4″MPT
Outlet 1/4″MPT
Max Water Temperature 190F
Max Internal Pressure 50PSI
Self Priming No
Wet End Polypropylene Front and Rear Housing, Impeller
Specialty General